Metsl Vital Track 12
- 12.1″ Color LCD with multichannel waveform display.
- Light Weight, Easy to carry, suitable for ambulance center
- Easy connecting with central monitoring system via Ethernet/Wireless
- 200 Hours Data Storage
- Simple & Easy operation
- Suitable for adult, pediatrics and neonates
- Standard parameters: 3/5/12 Lead ECG, SPO2, Nibp, 2-Temp
- Optional parameters:- EtCO2, 2 IBP
- Thermal Recorder & wall installation
- Controlled by both knob and touch screen.
Technical Specification
ECG
Parameter | Details |
---|---|
Electrode | 3/5/12 Leads |
Numeric Data Display | 6 lead ECG with HR, Heart Rate, VPC rate (per min.), ST Level, respiration rate, NIBP (Systolic, Diastolic, MAP), SpO2 (Nellcor), Pulse rate, Temperature, Heart rate sync mark, Pulse rate sync mark, respiratory sync mark |
Lead | LaVR, aVL, aVF, V (5 Lead), III or III (3 Lead), JJIIlaVR, avi, aVF, V1-V6 (12 Lead) |
Gain Selection | x1/4, x1/2, x1 and x2 |
Frequency Response | Diagnostic: 0.05 to 90 Hz, Monitor: 0.5 to 35 Hz, Surgery: 1-15 Hz |
Calibration Signal | 1 (mV p-p), Accuracy: ±5% |
Analysis | ST Segment & Arrhythmia Detection |
Display Channel | 6 Channels |
Sweep Speed | 6.25, 12.5, 25 or 50 mm/s |
Nibp
Parameter | Details |
---|---|
Technique | Oscillometric during inflation |
Range | Adult: 0-300 mm Hg Pediatric: 0-250 mm Hg Neonate: 0-135 mm Hg |
Measurement Cycle | <40 sec, typical |
Cycles (Selectable) | 2, 3, 5, 10, 15, 30 min, 1, 2, 4 hr |
Max. Allowable Cuff Pressure | Adult: 297 ±3 mm Hg Pediatric: 240 ±3 mm Hg Neonate: 147 ±3 mm Hg |
Resolution | 1 mm Hg |
Transducer Accuracy | +2 mm Hg or +2% of reading |
Modes | Auto, Manual & STAT |
Pulse Oximetry (Nellcor)
Parameter | Details |
---|---|
Range | 0 to 100% |
Resolution | 1% |
Accuracy | 70% to 99% range ±1%, 40 to 69% range ±1% |
Method | Dual wavelength LED |
Heart (Pulse) Rate
Parameter | Details |
---|---|
Source | User Selectable: Smart, ECG, Plenth, Nibp |
Range | Adult: 15-300 bpm |
Pediatric: 15-350 bpm | |
Accuracy | +1 bpm or ± 1% |
Environment
Parameter | Details |
---|---|
Operating Temperature | 10-40 °C |
Storage Temperature | -5-50 °C |
Humidity | 15% to 90% |
Temperature (Dual Channel)
Parameter | Details |
---|---|
Range, Accuracy | 0-50 °C ±1% |
Display Resolution | ±0.1°C |
Probe | YSI 400 and YSI 700 Series |
Probe Gradation | 1/10 Degree |
IBP (Optional)
Parameter | Details |
---|---|
Channels | 2 Nos |
Pressure | ART, PA, CVP, RAP, LAP, ICP P1, P2 |
Range | 0-300, 6-120, 10-300 mmHg |
Accuracy | +1 mmHg or ± 2% |
Trends
Parameter | Details |
---|---|
Memory | 200 Hr at 30 seconds intervals for a NIBP reading every 5 minutes |
Display | Tabular, graphical |
General
Parameter | Details |
---|---|
Dimensions | 320 (L) x 280 (B) x 135 (T) mm |
Weight | 3.5 Kg |
Power | AC 100-240 V, 50/60 Hz |
Power Consumption | 35 W |
Battery | 14.8 V/2200 Mah Li-Ion |
Recharge Time | 4.5 hours |
Operating Time | > 2 Hours typical |
Alarm Silence | 120 seconds |
Alarm Type | 3 Level adjustable Audio-visual alarms for each parameter, Sensor/Cuff disconnect, Low battery |
Electrical Safety | ESU, Defibrillator protection |
Connectivity | WiFi/ USB/Ethernet port/ LAN |
EtCO2 (Optional)
Parameter | Details |
---|---|
Transducer Type | Side stream CO2 sensor |
Range | 0-150 mm Hg |
Resolution | 0.1 mm Hg |
Accuracy | 0-40 mmHg: ±2 mm 41-70 mmHg: ±5% of reading 71-100 mmHg: ±8% of reading 101-150 mmHg: ±10% of reading |
Respiration Rate
Parameter | Details |
---|---|
Method | Impedance Pneumography |
Rate | Adult: 0-120 rpm Neo/Ped: 0-150 rpm |
Threshold Control | Yes |
Resolution | 1 rpm |
Accuracy | ±2 breath/min |