Metsl - VPM50

Features
- 12.1″ Color LCD with multichannel waveform display
- Lightweight and easy to carry
- Easy connection with central monitoring system
- 200 hours of data storage
- Simple and easy operation
- Suitable for adults, pediatrics, and neonates
- Standard parameters: 3/5 Lead ECG, SPO2, NIBP, 2-Temp
- Upgradable to EtCO2 & IBP
- Controlled by knob & touch screen
- CMS via Ethernet/Wireless
Technical Specifications
ECG
Parameter | Details |
---|---|
Electrode | 3 or 5 Leads |
Display | 7 lead ECG with HR |
Lead | – 5 Lead: I, II, III, aVR, aVL, aVF, V – 3 Lead: I, II, or III |
Gain Selection | x1/4, x1/2, x1, x2 |
Frequency Response | – Diagnostic: 0.05 to 90 Hz – Monitor: 0.5 to 35 Hz – Surgery: 1 to 15 Hz |
Calibration Signal | 1(mVp-p), Accuracy: ±5% |
Analysis | ST Segment & Arrhythmia Detection |
Display Channel | ST Segment & Arrhythmia Detection |
Pulse Oximetry
Parameter | Details |
---|---|
Range | 0 to 100% |
Resolution | 1% |
Accuracy | – 70% to 99%: ±2% – 0% to 69%: Undefined |
Method | Dual wavelength LED |
Nibp
Parameter | Details |
---|---|
Technique | Oscillometric during inflation |
Range | – Adult: 40-270 mm Hg – Pediatric: 40-240 mm Hg – Neonate: 40-135 mm Hg |
Measurement Cycle | < 40 sec, typical |
Cycles (Selectable) | 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr |
Max. Allowable Cuff Pressure | – Adult: 297 ±3 mm Hg – Pediatric: 240 ±3 mm Hg – Neonate: 147 ±3 mm Hg |
Resolution | 1 mm Hg |
Transducer Accuracy | ±2 mm Hg or ±2% of reading |
Modes | Auto, Manual & STAT |
Temperature( 2 Channel)
Parameter | Details |
---|---|
Range & Accuracy | 0-50 °C ±0.1°C |
Display Resolution | ±0.1°C |
Probe | YSI 400 and YSI 700 Series |
Unit | Celsius or Fahrenheit |
Respiration Rate
Parameter | Details |
---|---|
Rate | – Adult: 0-120 rpm – Neo/Ped: 0-150 rpm |
Resolution | 1 rpm |
Accuracy | ±2 breaths/min |
Heart (Pulse) Rate
Parameter | Details |
---|---|
Source | User Selectable: Smart, ECG, SpO2, NIBP |
Range | – Adult: 15-300 bpm – Pediatric: 15-350 bpm |
Accuracy | ±1 bpm or ±1% |
IBP(Optional)
Parameter | Details |
---|---|
Channels | 2 Nos |
Pressure | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Range | 0-300 mmHg, 6-120 mmHg, 10-300 mmHg |
Accuracy | ±1 mmHg or ±2% |
Environment
Parameter | Details |
---|---|
Operating Temperature | 59-95°F (15°-35°C) |
Storage Temperature | 23-122°F (-5°-50°C) |
Humidity | 15% to 90% |
Trends
Parameter | Details |
---|---|
Memory | 200 Hr at 30-second intervals for an NIBP reading every 5 minutes |
Display | Tabular, Graphical |
General
Parameter | Details |
---|---|
Dimensions | 320 (L) x 280 (B) x 135 (T) mm |
Weight | 3.5 Kg |
Power | AC 100-240 V, 50/60 Hz |
Power Consumption | 35 W |
Battery | 14.8 V / 2600 mAh Li-Ion |
Recharge Time | 4.5 hours |
Operating Time | > 6 hours typical |
Alarm | 3 Level Adjustment |
Printer | Inbuilt Thermal Recorder (Optional) |
Standard Accessories
Standard Accessories | Quantity |
---|---|
Finger Probe | 1 No |
Mains Cable | 1 No |
Cuff (Adult) | 1 No |
5-Lead ECG Cable | 1 No |
Temperature Probe | 1 No |